Fire suppression law in Scotland — the straight answer

Automatic fire suppression is a building standards requirement for a defined list of building types under Standard 2.15. This page sets out which buildings, which design standards actually apply, and what the recent changes mean.

System design document and floor plan showing a marked pipework route

Illustrative image.

WHO IT APPLIES TO

The building types named in Standard 2.15

Standard 2.15 doesn’t apply to every building. It names specific categories — if yours is on the list, suppression is a statutory requirement rather than a design choice.

Flats, maisonettes and social housing

Buildings containing flats or maisonettes, and social housing dwellings, are named categories under the standard.

Sheltered and extra care housing

Sheltered housing complexes are named in the standard, and new developments of this type require suppression as a matter of law.

Shared multi-occupancy residential

Shared multi-occupancy residential buildings are a named category. Whether a particular HMO falls inside it depends on the building — we’ll tell you straight.

Care, schools and shopping centres

Residential care buildings, school buildings and enclosed shopping centres complete the list of named building types.

THE STANDARDS

Which design standard actually applies

This is where most of the confusing advice circulates. Here is the position as it stands.

BS 8458 was withdrawn in 2025

BSI withdrew BS 8458:2015, the code of practice for residential and domestic water mist, in July 2025.

BS EN 14972-17 is the current BSI standard

BS EN 14972-17:2025 is now the recognised British Standard for residential water mist system design and testing.

Scotland’s handbooks still cite BS 8458

The Scottish building standards technical handbooks name BS 8458:2015-TC for water mist design, alongside BS 8663-1:2019 for nozzles. Systems designed to it remain compliant.

“No longer accepted” is wrong

You may be told water mist is no longer accepted by building control since the withdrawal. That is not what a withdrawal means, and it is not what the handbooks say.

RECENT CHANGES

Two changes worth knowing about

Both of these have landed since the standard was last widely discussed, and both are regularly misreported.

The November 2024 Direction

Dispenses most loft and attic conversions, and ground-storey extensions to flats, maisonettes and social housing, from the suppression requirement, provided set fire safety conditions are met. Read the guide →

Simon and Richard’s Law

In force since 6 April 2026. Traditionally constructed buildings converted to hotel use with 15 or more rooms used for sleeping accommodation now require automatic fire suppression.

SIMON AND RICHARD’S LAW

Does water mist satisfy it?

The law is named after Simon Midgley and Richard Dyson, who died in the Cameron House Hotel fire in December 2017. It follows the Fatal Accident Inquiry into their deaths.

The formally adopted recommendation, set out in the Scottish Government’s Business and Regulatory Impact Assessment, uses the generic term “automatic fire suppression systems” — the same wording used elsewhere in Standard 2.15 — rather than mandating sprinklers specifically. The government’s own cost modelling for larger hotels does assume sprinklers as the expected route, and we would rather say that plainly than pretend otherwise.

Water mist can be proposed as an alternative where the designer satisfies the local authority verifier — the same case-by-case route that applies to care homes. If your conversion sits near the 15-room threshold, that is a conversation worth having early rather than late.

FAQ

Common questions

What is Simon and Richard’s Law?

A change to Standard 2.15 requiring automatic fire suppression in traditionally constructed buildings converted to hotel use with 15 or more rooms used for sleeping accommodation, in force since 6 April 2026.

Does it apply to every hotel conversion?

No. It applies to conversions of traditionally constructed buildings to hotel use at 15 or more sleeping rooms. Smaller conversions may fall outside it, though other Standard 2.15 triggers could still apply.

Is my existing BS 8458 system still compliant?

Yes. A withdrawn standard does not invalidate systems designed to it, and the Scottish handbooks still cite BS 8458 for water mist design.

Who decides whether water mist is acceptable?

Your local authority verifier, on a case-by-case basis, where the designer makes the case. We produce the documentation that supports it.

Designed to BS 8458

Residential and domestic water mist systems, designed to the standard Scotland’s building standards cite.

Qualified installers

Fitted and commissioned by qualified plumbers, backed by 19 years of frontline firefighting.

Building warrant support

Design and consultancy for architects, builders and developers.

Not sure whether Standard 2.15 applies to your building?

Tell us what you’re working with and we’ll give you a clear, written answer — including when the honest answer is that you don’t need a system at all.

Open-plan kitchen with an island, pendant lights and living area