Water mist for sheltered and extra care housing

In Scotland, new sheltered and extra care housing developments must be protected by an automatic fire suppression system — sprinkler or water mist. We design around residents who may need more time to reach safety.

Communal lounge in a sheltered housing development

Illustrative image.

WHY IT MATTERS

Protection designed around the residents

Specialised housing carries a different risk profile to general needs housing, and the standards reflect that.

A legal requirement, not a recommendation

Scottish building standards require automatic suppression in new sheltered and extra care housing developments.

Built around residents’ needs

Fast-acting, discreet protection suited to residents with reduced mobility or additional support needs, who may not be able to evacuate quickly.

No disruptive plant room

Mains-fed pipework needs no large storage tank or dedicated plant room — which matters when the floor area is already committed to care facilities.

Certified for your building warrant

Design and documentation matched to what your building control officer and verifier expect to see, handed over as standard.

COMPLIANCE

Where this sits in the standards

Sheltered housing complexes are a named building type under Standard 2.15 of the Scottish building standards, which is what makes suppression a statutory requirement for new developments rather than a specification choice.

It sits alongside the National Fire Chiefs Council guidance on fire safety in specialised housing, which deals with the wider question of how fire strategy should work in buildings where some residents cannot self-evacuate. A suppression system is one part of that picture, not the whole of it, and we will say so.

Our systems are designed and documented to the water mist standard cited in the current Scottish handbooks, with the certification your verifier will ask for at design and completion stage.

FAQ

Common questions

Is suppression required in existing sheltered housing?

The statutory requirement bites on new developments. Existing stock is usually driven by the fire risk assessment and the landlord’s own fire strategy rather than by Standard 2.15 directly.

Will the system disturb residents once fitted?

No. It sits dormant until heat triggers an individual nozzle, and routine servicing is quick and scheduled around the residents.

Can it be retrofitted into occupied housing?

Usually yes. Slim mains-fed pipework is far less invasive than sprinkler installation, which is what makes retrofit into occupied specialised housing realistic.

Designed to BS 8458

Residential and domestic water mist systems, designed to the standard Scotland’s building standards cite.

Qualified installers

Fitted and commissioned by qualified plumbers, backed by 19 years of frontline firefighting.

Building warrant support

Design and consultancy for architects, builders and developers.

Planning a sheltered or extra care development?

Bring us in early and we’ll tell you what Standard 2.15 requires for your scheme, and what it will take to satisfy your verifier.